General Rules for Wiring of Domestic & Industrial
75
1. The current rating of the conductor should be as per requirement of the load.
2. There should be a circuit breaker or a linked switch with a fuse on each live conductor of the supply mains at the point of entry.
3. The switch or fuse unit need not be on the neutral wire.
4. All main switches should either be of metal clad enclosed pattern or of any insulated enclosed pattern fixed near the point of entry of the supply.
5. The location of the main board should be such that it is easily accessible to fire-men and personnel to quickly disconnect the supply in case of emergencies.
6. Main switchboards should have the provisions for locking as a safeguard against tampering by unauthorized persons.
7. The switchboard should not be erected above gas stoves or sinks or within 2.5m of any washing unit in washing rooms.
8. Adequate illumination should be provided for all working spaces above the switchboard when installed indoors.
9. For small installations connected to a single phase 240V supply, wooden boards must be used as main boards or sub-boards.
10. Every circuit or apparatus should be provided with separate switches.
11. All the motor starters and switches should be accessible to the operator.
12. The circuit should be designed with a provision for 20% increase in load due to future modifications.
13. When the wiring in an installation has been completed it should be tested before giving the supply and any leakage in the wiring should not exceed 1/5000 of the maximum current of the load.
14. In any building, light wiring and power wiring should be kept separate.
15. All distribution boards in the circuit should be installed at a height of not more than 2m above the floor level.
16. In three phases, four wire installations, the load should be equally divided on all three phases.
17. Ceiling roses should not be used in a circuit where the voltage exceeds 250V
18. Ordinary socket outlets may be fixed at any place, at a height above 20cm from the floor level.
19. Each 15A socket outlet for the use of domestic appliance should be of the controlled type and should have its own individual fuse.
20. In an earthed system of supply, a socket outlet with plug should be of three pin type with the third terminal connected to earth.
21. All lamps, unless otherwise required should be suitably protected and hang at a height of not less than 2.5m above the floor level.
22. The control of a ceiling fan should be through its own regulator as well as through a switch in series.
|
Wiring a House (For Pros by Pros)
Price: $9.98
List Price: $24.95 |
|
House Wiring with the NEC
Price: $65.92
List Price: $54.95 |
|
Black & Decker Complete Guide to Wiring: Upgrade Your Main Service Panel - Discover the Latest Wiring Products - Complies with 2008 NEC
Price: $15.67
List Price: $24.99 |
|
Residential Construction Academy: House Wiring
Price: $86.95
|
|
Black & Decker Advanced Home Wiring: Updated 2nd Edition, Run New Circuits, Install Outdoor Wiring
Price: $10.30
List Price: $16.99 |
|
|
Open House H616 4 X 6 Telephone Master Hub
Price: Too low to display
List Price: $37.00 |
|
|
Dollhouse Basic Wiring Kit no transformer by Miniature House
Price: $25.99
|
- ITEMS OF PRIMARY SUBSTATION
A typical substation will contain line termination structures, high-voltage switchgear, one or more power transformers, low voltage switchgear, surge protection, controls, grounding (earthling) system, and... - OVERHEAD TRANSMISSION LINES
A transmission line has three constants R, L and C distributed uniformly along the whole length of the line. The resistance and inductance form the series impedance. The capacitance existing between... - ELECTRICAL HIGH VOLTAGE CIRCUIT BREAKERS
Electrical power transmission networks are protected and controlled by high-voltage breakers. In substations the protection relay scheme can be complex, protecting equipment and busses from various types of... - INSTRUMENT TRANSFORMES
These can be classified in to two parts. They are, Current Transformers and Potential Transformers. These transformers are generally used to measure the high voltages and high currents. In power stations and...
PrintShare it! — Rate it: up down flag this hub









khan says:
5 weeks ago
bhenchod